1. The core goal of humidifier inspection

Ensure that products meet safety, functionality, durability and regulatory requirements , focusing on the following aspects:

  • Electrical safety (anti-electric shock, overheating, leakage, etc.)

  • Performance verification (humidification efficiency, water volume control, noise, etc.)

  • Material and chemical compliance (non-toxic, no release of hazardous substances)

  • User experience (ease of operation, accuracy of instructions)

2. Key inspection items

(1) Appearance and structure inspection

  • Shell quality : no scratches, deformation, even seams, clear markings.

  • Water tank sealing : no leakage after filling with water, and the lid is closed firmly.

  • Accessories integrity : filter, remote control (if any), power cord, etc. are complete.

(2) Electrical safety test

  • Insulation resistance : Moisture test ≥ 2MΩ.

  • Ground continuity : resistance ≤ 0.1Ω (Class I electrical appliances).

  • Withstand voltage test : high voltage 1500V/1min without breakdown.

  • Anti-dry-burn protection : Automatically cut off the power when there is no water (ultrasonic type needs to be checked carefully).

(3) Performance testing

  • Humidification capacity : measured value ≥ 90% of the nominal value (e.g. nominal value is 300ml/h, measured value must be ≥ 270ml/h).

  • Water level control : Sensitive automatic shutdown function (power failure when water level is too low or water tank is removed).

  • Noise : Operating noise ≤ nominal value + 3dB(A), usually required to be ≤40dB (sleep mode).

(4) Materials and chemical safety

  • Water tank material : must be food grade plastic (such as PP, ABS), without irritating odor.

  • Antibacterial function (as claimed): The antibacterial rate of the filter or water tank is ≥90% (test report required).

  • Ozone release (ionization): concentration ≤ 0.05ppm.

(5) User experience and functionality

  • Operation interface : buttons/touch screen are sensitive and mode switching is smooth.

  • Humidity sensor : The error between displayed and actual humidity is ≤±5% (if equipped with intelligent adjustment function).

  • App/remote control function (if applicable): The connection is stable and the command response is timely.

3. Common Defects and Risks

  • Water leakage problem : water tank design defects or aging of the sealing ring.

  • Electrical failure : Insufficient waterproofing of the circuit board causes a short circuit.

  • False claims : The actual humidification capacity or antibacterial performance does not meet the standards.

  • Hazardous substances : Low-quality plastics release VOCs (volatile organic compounds).

4. Inspection process

  1. Sampling : Sampling according to AQL 2.5 standard or customer requirements.

  2. Unpacking inspection : Check the completeness of the packaging, instructions, and accessories.

  3. Power-on test : operation in each gear and verification of automatic protection functions.

  4. Safety test : grounding, withstand voltage, leakage current, etc.

  5. Performance spot check : laboratory retest of humidification capacity, noise, etc. (if necessary).

  6. Report issuance : Provide a graphic inspection report and mark any unqualified items.

5. Applicable standards and regulations

  • China : GB 4706.1 (General safety of household appliances), GB 4706.48 (Special requirements for humidifiers).

  • International : UL 998 (US), EN 60335 (EU), PSE (Japan).